Live demo — data resets daily at 03:00 UTC. Nothing you enter is saved. Maestro UI →

TC-F-01 — VMON calibration — voltage readback accuracy (Ch1 & Ch2)

pass · functional · Signal: EN2n, VOUT2

Measurement

NominalTolerance %Pass Criterion

VMON1 and VMON2 ADC readback can be calibrated such that reported voltage matches actual output voltage within ±1% across the 5–24V range on both channels independently.

Covers Requirements

CodeTitleStatus
REQ-001 Maximum output voltage 24V per channel approved