TC-P-01 — Load regulation — 0→3.0A at 24V (Ch1 & Ch2 parallel)
open · performance · Signal: VOUT1, VOUT2, IOUT
Measurement
| Nominal | Tolerance % | Pass Criterion |
|---|---|---|
| 24.000000 | 2.0000 | VOUT remains within ±2% of 24V (23.52–24.48V) across combined load sweep 0→3.0A with both channels connected in parallel. 20V in. |
Covers Requirements
| Code | Title | Status |
|---|---|---|
REQ-002 |
Maximum continuous output current 1.5A per channel | approved |