Live demo — data resets daily at 03:00 UTC. Nothing you enter is saved. Maestro UI →

TC-P-04 — 8-hour stability — VOUT drift at 24V/1A

open · performance · Signal: VOUT1, VOUT2

Measurement

NominalTolerance %Pass Criterion
24.000000

|ΔVOUT1| ≤ 24mV and |ΔVOUT2| ≤ 24mV (±0.1% of 24V) between t=0 and t=8h. Both channels active at VOUT=24V, ILOAD=1A/ch, 25°C ambient, 20V in.

Covers Requirements

CodeTitleStatus
REQ-004 Output voltage drift ≤ ±0.1% over 8 hours approved
REQ-006 CC limit linearity ≤ ±0.1% FS over active ISET range approved