TC-S-01 — System fault indicators — FAULT_PSU1_N / FAULT_PSU2_N signalling
open · functional
Measurement
| Nominal | Tolerance % | Pass Criterion |
|---|---|---|
| — | — | FAULT_PSU1_N and FAULT_PSU2_N both read LOW (asserted) when a fault is injected on the respective channel, and return HIGH (deasserted) when the fault is cleared. |
Covers Requirements
| Code | Title | Status |
|---|---|---|
REQ-004 |
Output voltage drift ≤ ±0.1% over 8 hours | approved |