REQ-047 — Prioritise USB over battery when USB connected

approved · Functional · Approved by migrated

Statement

When USB is connected, the power path management shall prioritise USB over battery, supplying the system from VBUS and simultaneously charging the battery.

Acceptance Criteria

With USB and battery both connected, system load is sourced from USB; battery charge current flows simultaneously.

Linked Test Cases

CodeTitleStatus
TC-P-01 Charge current measurement open