Live demo — data resets daily at 03:00 UTC. Nothing you enter is saved. Maestro UI →

TC-P-05 — 3.3V rail — under load (WiFi active)

open · functional · Signal: 3V3

Measurement

NominalTolerance %Pass Criterion
3.300000 5.0000

3.3V rail within ±5% with ESP32 in active WiFi TX mode at VBAT=3.7V

Covers Requirements

CodeTitleStatus
REQ-006 3.3V rail from BQ24075 SYS pin approved
REQ-048 Simultaneous charging and system operation approved