TC-L-01 — SX1276 DIO0 interrupt routing

open · functional

Measurement

NominalTolerance %Pass Criterion

DIO0 rising edge triggers interrupt on ESP32 IO5 within 1 ms of TX-done or RX-done event

Covers Requirements

CodeTitleStatus
REQ-052 SX1276 DIO0 interrupt on IO5 approved