REQ-021 — Accordion A2 DAQ interface

approved · Interface · Approved by demo

Statement

The adapter shall provide an interface to Accordion A2 for use as DAQ hardware during automated production testing.

Acceptance Criteria

Accordion A2 connectable to adapter; communication established and DAQ signals accessible.

Linked Test Cases

CodeTitleStatus
V-21 Verify: Accordion A2 DAQ interface pass

Sign-offs

StageSigned byRoleWhenAttestation
approved demo Test Engineer 2026-06-26 02:45 Approved for the R1 verification baseline.