REQ-011 — Battery Voltage Monitoring

approved · Functional · Approved by demo

Statement

The battery voltage shall be monitored via a 1:2 voltage divider (2×1 MΩ resistors) connected to ADC channel 0. The divider shall be software-disconnectable to prevent quiescent drain during deep sleep. Quiescent drain when active shall not exceed 5 µA.

Acceptance Criteria

Battery monitoring net measures half of battery rail voltage. Divider disconnected in deep sleep. Quiescent drain ≤ 5 µA when enabled.

Linked Test Cases

CodeTitleStatus
TC-A-00 Battery voltage divider at VBAT=4.2V open
TC-A-01 Battery voltage divider at VBAT=3.0V open
TC-A-02 Battery divider disconnect in deep sleep open

Sign-offs

StageSigned byRoleWhenAttestation
approved demo 2026-06-05 06:42