REQ-004 — Charge Status Indication
approved · Functional · Approved by demo
Statement
Charge status shall be indicated via the CHG and PG outputs of the BQ24075 during active charging and when charging is complete.
Acceptance Criteria
CHG pin asserted during charging; PG pin asserted when power good; status observable.
Linked Test Cases
| Code | Title | Status |
|---|---|---|
TC-P-02 |
Charge status LED | pass |
Sign-offs
| Stage | Signed by | Role | When | Attestation |
|---|---|---|---|---|
| approved | demo | — | 2026-06-05 06:42 | — |