SIG-07 — Fixed Load 2.2 kΩ (4 channels)
draft · Signal
Statement
Fixed Load (4 channels): switchable 2.2 kΩ to GND with voltage monitoring
Acceptance Criteria
RLOAD 2156–2244 Ω; VMEAS range 0–5 V; VMEAS gain error ±1.6%; offset ±6 mV
Sign-offs
No sign-offs recorded. Approving a requirement records one here.