Mini-PSU

ESH10000662 · Rev R1

in_progresselectronics

2-channel programmable buck-boost PSU Comtop Module. LT3942-based converters, 20V input, 0–24V/1.5A per channel output, DAC-controlled (VSET/ISET via AD5593R). VMON1/VMON2 output monitoring, PWM1n/PWM2n GPIO outputs via PI4IOE5V6416 expander. R1 adds VMON monitoring (ECO-012/013) and PWM expander relocation (ECO-010/011).

100% Coverage
17% Done
6 Requirements
25 Test Cases
1 Blockers
3 Open Entries

Timeline

Color = derived gate state · hover a tile for its note.
overdue / blocked
🏁 Release
· 3/6

Status & gates

Chronological — Release is the final gate. Derived & read-only; edit via please_milestone_* tools.
Release / Readiness overdue / blocked 3/6 met1 failing
pending Requirements approved
  • REQ-007: draft
  • REQ-008: draft
met Coverage ≥ 100%
  • 6/6 requirements covered (100%)
failing All test cases pass
  • 14/25 passed
  • 1 failing: TC-B-02
  • 10 not yet run
pending No blocking issues open
  • E-009: open blocker
met Deviations resolved
met Interfaces frozen
Blocked 1 blocking entry

Test Cases

14 Pass 1 Fail / Deviated 0 N/A 10 Open0 / 25 Maestro impl.

Coverage — 100.0% · Done — 16.7%

4 of 4
CodeKindTitleSeverityScopeStatusCreated
E-008 notice R24/R58 38.3kΩ applied to DUT-01 — BOM and ECO-015 not yet updated info action open 2026-05-27
E-009 notice BLOCKING: REQ-002 (1.5A/ch @ 24V) not demonstrated — R17/R49 rework pending blocking action open 2026-05-27
E-010 decision Rename OUT1n/OUT2n → OUT1_N/OUT2_N warning action open 2026-05-27
E-011 issue CH2 quiescent current ~15% over target at 20V idle warning action open 2026-06-04