Live demo — data resets daily at 03:00 UTC. Nothing you enter is saved. Maestro UI →

REQ-003 — PCB hotspot ≤ 50°C at full load

approved · Performance · Approved by migrated

Statement

The device shall not exceed 50°C (case / PCB hotspot) at full load and 25°C ambient.

Acceptance Criteria

Thermal measurement at VOUT=24V, ILOAD=1.5A per channel (both channels active), 25°C ambient; no point on case or PCB exceeds 50°C after thermal soak (30 min minimum). Measure at L1, L2, U1, U3, L3, L4.

Linked Test Cases

CodeTitleStatus
TC-T-00 Thermal soak — PCB hotspot at full load (24V/1.5A/ch) open
TC-S-03 Output switch — OUT1/OUT2 MOSFET on/off control pass
TC-S-00 Converter enable switches — EN1n / EN2n control pass

Sign-offs

No sign-offs recorded. Approving a requirement records one here.