TC-T-00 — Thermal soak — PCB hotspot at full load (24V/1.5A/ch)
open · performance · Signal: L1, L2, U1, U3, L3, L4
Measurement
| Nominal | Tolerance % | Pass Criterion |
|---|---|---|
| — | — | No point on PCB or case exceeds 50°C after ≥30 min soak at VOUT1=VOUT2=24V, ILOAD1=ILOAD2=1.5A, 25°C ambient, no forced airflow. Measure at L1, L2, U1, U3, L3, L4 using thermal camera or thermocouple. |
Covers Requirements
| Code | Title | Status |
|---|---|---|
REQ-003 |
PCB hotspot ≤ 50°C at full load | approved |