REQ-004 — Output voltage drift ≤ ±0.1% over 8 hours

approved · Performance · Approved by demo

Statement

Output voltage drift shall not exceed ±0.1% over 8 hours of continuous operation.

Acceptance Criteria

VOUT measured at t=0 and t=8h; VOUT=24V, ILOAD=1A per channel, both channels active; |ΔVOUT| ≤ 0.1% of setpoint (≤±24mV).

Linked Test Cases

CodeTitleStatus
TC-S-01 System fault indicators — FAULT_PSU1_N / FAULT_PSU2_N signalling pass
TC-S-02 UVLO/OVLO — under- and over-voltage lockout on VT rail pass
TC-F-03 ISET calibration — current limit setpoint accuracy (Ch1 & Ch2) pass
TC-F-04 IMON calibration — current readback accuracy (Ch1 & Ch2) fail
TC-P-04 8-hour stability — VOUT drift at 24V/1A fail