TC-SW-01 — Pin-strap bring-up power enable (no MCU)

open · functional

Measurement

NominalTolerance %Pass Criterion

With pin-strap applied (jumper or resistor strap as defined), system power enabled without MCU firmware present; U10 output live at 20V.

Covers Requirements

CodeTitleStatus
REQ-017 Power via pin-strap w/o MCU Firmware approved