TC-D-03 — UART net pull-up resistors at J9

open · functional

Measurement

NominalTolerance %Pass Criterion

4.7kΩ pull-up resistors to 3V3 present on M2TxD, M2RxD, M2RTS, M2CTS at J9; confirmed in schematic BOM audit and net continuity.

Covers Requirements

CodeTitleStatus
REQ-035 Pull-up resistors 4.7kΩ on UART nets at J9 approved