REQ-004 — Output voltage drift ≤ ±0.1% over 8 hours
draft · Performance
Statement
Output voltage drift shall not exceed ±0.1% over 8 hours of continuous operation.
Acceptance Criteria
VOUT measured at t=0 and t=8h; VOUT=24V, ILOAD=600mA per channel, both channels active; |ΔVOUT| ≤ 0.1% of setpoint (≤±24mV).
Sign-offs
No sign-offs recorded. Approving a requirement records one here.