REQ-005 — Load transient ≤ 1% overshoot, recovery ≤ 5µs
draft · Performance
Statement
Output voltage overshoot and undershoot on a 0A→600mA load step shall not exceed 1% of setpoint, with recovery within 5µs.
Acceptance Criteria
0A→600mA load step applied per channel; peak overshoot/undershoot ≤ 1% of VOUT setpoint (≤240mV at 24V); output returns to within ±1% of setpoint within 5µs. Both channels active.
Sign-offs
No sign-offs recorded. Approving a requirement records one here.