REQ-F-04 — On power-up, the unit shall enter standby state with the boost output disabled (output terminals at 0 V) and the blue output LED illuminated. The BTL flip-flop shall power on in the reset state.
approved · Functional
Statement
On power-up, the unit shall enter standby state with the boost output disabled (output terminals at 0 V) and the blue output LED illuminated. The BTL flip-flop shall power on in the reset state.
Acceptance Criteria
10 consecutive power-cycles shall be performed. In each cycle the output voltage shall be below 0.1 V and the blue LED shall be lit within 100 ms of power application, before any button press.
Linked Test Cases
| Code | Title | Status |
|---|---|---|
TC-F-04 |
Power-on standby — 10 consecutive power cycles | pass |
Sign-offs
No sign-offs recorded. Approving a requirement records one here.