REQ-F-05 — With the override DIP switch off, each press of the run button shall toggle the unit between run (output enabled) and standby (output disabled) states via the BTL D-type flip-flop. The toggle shall be debounced and shall be immune to contact bounce of up to 5 ms.

approved · Functional

Statement

With the override DIP switch off, each press of the run button shall toggle the unit between run (output enabled) and standby (output disabled) states via the BTL D-type flip-flop. The toggle shall be debounced and shall be immune to contact bounce of up to 5 ms.

Acceptance Criteria

20 consecutive button presses shall be logged. Each press shall produce exactly one state transition. Output voltage shall track state: present at target voltage in run, ≤0.1 V in standby.

Linked Test Cases

CodeTitleStatus
TC-F-05 Button run/standby toggle — 20 consecutive presses pass

Sign-offs

No sign-offs recorded. Approving a requirement records one here.