REQ-F-06 — When the override DIP switch is set to ON, the external 2-pin terminal (dry contact) shall override the button: shorting the terminal shall enable the output (run); opening the terminal shall disable the output (standby). The button shall have no effect in this mode.
approved · Functional
Statement
When the override DIP switch is set to ON, the external 2-pin terminal (dry contact) shall override the button: shorting the terminal shall enable the output (run); opening the terminal shall disable the output (standby). The button shall have no effect in this mode.
Acceptance Criteria
With OVR=1: (1) short ext terminals — output shall reach target voltage within 500 ms; (2) open ext terminals — output shall drop to ≤0.1 V within 500 ms. Button presses during OVR=1 shall produce no state change.
Linked Test Cases
| Code | Title | Status |
|---|---|---|
TC-F-06 |
External terminal override (OVR=1): short and open | pass |
VAL-03 |
System validation: override DIP ON + short ext terminals → output runs | pass |
VAL-04 |
System validation: override DIP ON + open ext terminals → standby | pass |
Sign-offs
No sign-offs recorded. Approving a requirement records one here.