Live demo — data resets daily at 03:00 UTC. Nothing you enter is saved.

REQ-F-06 — When the override DIP switch is set to ON, the external 2-pin terminal (dry contact) shall override the button: shorting the terminal shall enable the output (run); opening the terminal shall disable the output (standby). The button shall have no effect in this mode.

approved · Functional

Statement

When the override DIP switch is set to ON, the external 2-pin terminal (dry contact) shall override the button: shorting the terminal shall enable the output (run); opening the terminal shall disable the output (standby). The button shall have no effect in this mode.

Acceptance Criteria

With OVR=1: (1) short ext terminals — output shall reach target voltage within 500 ms; (2) open ext terminals — output shall drop to ≤0.1 V within 500 ms. Button presses during OVR=1 shall produce no state change.

Linked Test Cases

CodeTitleStatus
TC-F-06 External terminal override (OVR=1): short and open pass
VAL-03 System validation: override DIP ON + short ext terminals → output runs pass
VAL-04 System validation: override DIP ON + open ext terminals → standby pass

Sign-offs

No sign-offs recorded. Approving a requirement records one here.