REQ-F-08 — In standby state, the output disconnect switch (Q2 P-FET + Q3 N-FET level shift) shall physically break the inductor/diode conduction path so that the output terminals present true 0 V even with a passive load connected, not merely the residual boost diode drop.
approved · Functional
Statement
In standby state, the output disconnect switch (Q2 P-FET + Q3 N-FET level shift) shall physically break the inductor/diode conduction path so that the output terminals present true 0 V even with a passive load connected, not merely the residual boost diode drop.
Acceptance Criteria
With a passive load (≥1 kΩ) connected and unit in standby, output voltage shall be ≤0.1 V measured at the output terminals. Verified by measurement and simulation.
Linked Test Cases
| Code | Title | Status |
|---|---|---|
TC-F-08 |
Standby output voltage with passive load | pass |
Sign-offs
No sign-offs recorded. Approving a requirement records one here.