Live demo — data resets daily at 03:00 UTC. Nothing you enter is saved.

REQ-P-03 — The overtemperature protection shall trip at 75 °C ±5 °C measured at the PCB hot-spot NTC. The recovery threshold shall be at least 10 °C below the trip threshold (i.e. ≤ 65 °C). Implemented via NTC + reference divider feeding the LM339 comparator. NTC placement pending PCB layout (RT-207).

draft · Performance

Statement

The overtemperature protection shall trip at 75 °C ±5 °C measured at the PCB hot-spot NTC. The recovery threshold shall be at least 10 °C below the trip threshold (i.e. ≤ 65 °C). Implemented via NTC + reference divider feeding the LM339 comparator. NTC placement pending PCB layout (RT-207).

Acceptance Criteria

Slow-ramp NTC temperature using a controlled heat source. Record: (1) trip temperature (output disables); (2) recovery temperature (latch can be cleared). Trip shall be 70–80 °C; recovery shall be ≤ trip − 10 °C.

Sign-offs

No sign-offs recorded. Approving a requirement records one here.

Reconnecting

The connection to the server dropped. Trying to pick the session back up.

Attempt 1 of 30 — next try in 0s

Session paused

This tab was disconnected to free server resources. The session is still held, so it can be picked up where you left off.

Could not reconnect

The server stopped answering and the automatic attempts have run out. It may still come back — trying once more costs nothing.

Could not resume

The paused session could not be restored. Reloading starts a fresh one; anything typed into this page and not yet saved will be lost.

This session has ended

This page was connected to a server that has since restarted, so there is no session left to rejoin. Reloading picks up the new one; anything typed into this page and not yet saved will be lost.