Live demo — data resets daily at 03:00 UTC. Nothing you enter is saved.

Coverage Report

Generated 2026-10-24 22:35 UTC · 6 active requirements

Cov 100% · Done 50%
3 Done 3 Partial 0 Not Started 0 Missing 0 Obsolete
3 of 3
Code Title Category Linked Test Cases
REQ-003 PCB hotspot ≤ 50°C at full load Performance
REQ-004 Output voltage drift ≤ ±0.1% over 8 hours Performance
REQ-006 CC limit linearity ≤ ±0.1% FS over active ISET range Performance

Reconnecting

The connection to the server dropped. Trying to pick the session back up.

Attempt 1 of 30 — next try in 0s

Session paused

This tab was disconnected to free server resources. The session is still held, so it can be picked up where you left off.

Could not reconnect

The server stopped answering and the automatic attempts have run out. It may still come back — trying once more costs nothing.

Could not resume

The paused session could not be restored. Reloading starts a fresh one; anything typed into this page and not yet saved will be lost.

This session has ended

This page was connected to a server that has since restarted, so there is no session left to rejoin. Reloading picks up the new one; anything typed into this page and not yet saved will be lost.