Live demo — data resets daily at 03:00 UTC. Nothing you enter is saved.

REQ-P-01 — The output voltage at any of the seven selectable levels shall remain within ±5 % of the nominal target voltage across the full load range of 10 % to 100 % of rated output power. Verified by load sweep on physical hardware; simulation at 56 V shows ±open-loop offset (closed-loop sim pending LM5156 PSpice model).

approved · Performance

Statement

The output voltage at any of the seven selectable levels shall remain within ±5 % of the nominal target voltage across the full load range of 10 % to 100 % of rated output power. Verified by load sweep on physical hardware; simulation at 56 V shows ±open-loop offset (closed-loop sim pending LM5156 PSpice model).

Acceptance Criteria

Load sweep from 10 % to 100 % of rated load in steps of 10 % at each of the 7 output voltages. Output voltage shall remain within ±5 % of nominal at every load step. Note: open-loop simulation shows ~5 V offset at 56 V — hardware verification required.

Linked Test Cases

CodeTitleStatus
TC-P-01 Load regulation sweep — all 7 outputs, 10–100 % load pass

Sign-offs

No sign-offs recorded. Approving a requirement records one here.

Reconnecting

The connection to the server dropped. Trying to pick the session back up.

Attempt 1 of 30 — next try in 0s

Session paused

This tab was disconnected to free server resources. The session is still held, so it can be picked up where you left off.

Could not reconnect

The server stopped answering and the automatic attempts have run out. It may still come back — trying once more costs nothing.

Could not resume

The paused session could not be restored. Reloading starts a fresh one; anything typed into this page and not yet saved will be lost.

This session has ended

This page was connected to a server that has since restarted, so there is no session left to rejoin. Reloading picks up the new one; anything typed into this page and not yet saved will be lost.