Live demo — data resets daily at 03:00 UTC. Nothing you enter is saved.

REQ-P-01 — The output voltage at any of the seven selectable levels shall remain within ±5 % of the nominal target voltage across the full load range of 10 % to 100 % of rated output power. Verified by load sweep on physical hardware; simulation at 56 V shows ±open-loop offset (closed-loop sim pending LM5156 PSpice model).

approved · Performance

Statement

The output voltage at any of the seven selectable levels shall remain within ±5 % of the nominal target voltage across the full load range of 10 % to 100 % of rated output power. Verified by load sweep on physical hardware; simulation at 56 V shows ±open-loop offset (closed-loop sim pending LM5156 PSpice model).

Acceptance Criteria

Load sweep from 10 % to 100 % of rated load in steps of 10 % at each of the 7 output voltages. Output voltage shall remain within ±5 % of nominal at every load step. Note: open-loop simulation shows ~5 V offset at 56 V — hardware verification required.

Linked Test Cases

CodeTitleStatus
TC-P-01 Load regulation sweep — all 7 outputs, 10–100 % load pass

Sign-offs

No sign-offs recorded. Approving a requirement records one here.