TC-P-01 — Load regulation sweep — all 7 outputs, 10–100 % load

pass · Performance

Covers Requirements

CodeTitleStatus
REQ-P-01 The output voltage at any of the seven selectable levels shall remain within ±5 % of the nominal target voltage across the full load range of 10 % to 100 % of rated output power. Verified by load sweep on physical hardware; simulation at 56 V shows ±open-loop offset (closed-loop sim pending LM5156 PSpice model). approved