Live demo — data resets daily at 03:00 UTC. Nothing you enter is saved.

REQ-P-02 — The power conversion efficiency (Pout / Pin) shall be ≥ 90 % at rated output power (100 W). LTspice simulation v7 measured 95.2 % at 20 V in / 56 V out / 32 Ω load.

approved · Performance

Statement

The power conversion efficiency (Pout / Pin) shall be ≥ 90 % at rated output power (100 W). LTspice simulation v7 measured 95.2 % at 20 V in / 56 V out / 32 Ω load.

Acceptance Criteria

Measure Pin (Vin × Iin) and Pout (Vout × Iout) at rated load for each output voltage. Efficiency shall be ≥ 90 % at each point. Plot efficiency map across load range.

Linked Test Cases

CodeTitleStatus
TC-P-02 Efficiency map — ≥ 90 % at rated power per output pass

Sign-offs

No sign-offs recorded. Approving a requirement records one here.