TC-P-02 — Efficiency map — ≥ 90 % at rated power per output
pass · Performance
Covers Requirements
| Code | Title | Status |
|---|---|---|
REQ-P-02 |
The power conversion efficiency (Pout / Pin) shall be ≥ 90 % at rated output power (100 W). LTspice simulation v7 measured 95.2 % at 20 V in / 56 V out / 32 Ω load. | approved |