Live demo — data resets daily at 03:00 UTC. Nothing you enter is saved.

TC-P-02 — Efficiency map — ≥ 90 % at rated power per output

pass · Performance

Covers Requirements

CodeTitleStatus
REQ-P-02 The power conversion efficiency (Pout / Pin) shall be ≥ 90 % at rated output power (100 W). LTspice simulation v7 measured 95.2 % at 20 V in / 56 V out / 32 Ω load. approved